Copyright © 2018 Monthlery Electrical Materials (Changzhou) Co., Ltd. ALL RIGHTS RESERVED
Hotline:
Fax:0519-82799055
E-mail:mlryw@czmlr.com
Address:No. 277 Longxi Avenue,
Zhulin Town, Jintan District, Changzhou City
Product Center
PRODUCT CENTER
Product Center / Product center
Austenite/low temperature resistance
Standards compliant: GB/T17853 E308LT1-1
AWS A5.22 E308LT1-1
Characteristics and applications
1.High impact ductility under -196°C low temperature;
2.Featuring stable arc, little spatte, favorable detachability, stable wire feedability, beautiful appearance and other favorable welding performance;
3.Applicable to petrochemical engineering, low temperature storage tanks and vessels .
Welding position
Chemical composition (wt%)
Alloy wt% | C | Mn | Si | Cr | Ni | Mo | P | S | Cu |
GB/T | 0.04 | 0.5-2.5 | 1.0 | 18.0-21.0 | 9.0-11.0 | 0.50 | 0.040 | 0.030 | 0.50 |
AWS | 0.04 | 0.5-2.5 | 1.0 | 18.0-21.0 | 9.0-11.0 | 0.75 | 0.040 | 0.030 | 0.75 |
Case value | 0.02 | 1.25 | 0.42 | 19.58 | 9.60 | 0.04 | 0.022 | 0.003 | 0.03 |
Mechanical properties
Mechanical properties | Yield strength MPa | Tensile strength MPa | Elongation% | Impact valueJ /°C |
GB/T | - | 520 | 35 | - |
AWS | - | 520 | 30 | - |
Case value | - | 550 | 40 | 43/-196 |
Recommended current range: (DC+)
Diameter of welding wire (mm) |
1.2 | 1.6 |
Voltage (V) |
22-36 | 26-38 |
Current (A) |
120-260 | 200-300 |
Extension length (mm) |
15-20 | 18-25 |
Gas flow (l/min) |
15-25 | 15-25 |
Welding precautions
1.Using CO2 shielding gas with purity ≥99.98% and gas flow of 20-25L/min.
2.Interpass temperature: 16~100°C
3.During welding, please keep off wind to prevent welding defects caused by flying off shielding gas. Greasy dirt, water, etc. at welding parts shall be removed.
4.Welding wire shall be used up as quickly as possible after unpacking. Moisture-proof measures shall be adopted for those not used up.